Bently Nevada 1900/65A-01-00-03-00-00
· Product image is representative; revision or series may vary. Contact us to request a specific version.
Ships by Tuesday, September 22

1900/65A-01-00-03-00-00

General purpose equipment monitor

Shipping Information

  • For inventory products, we support same day shipping upon payment.
  • For urgent needs, we offer same-day shipping on most items for orders placed before 2:00 PM UTC+8 Simply mention your preferred next-day shipping when place the order, and your order will be prioritized to minimize downtime.
  • For indent items, typical turnaround is 1-3 weeks, depending on parts availability and scarcity.
Customs & Documentation
We prepare clear, order-specific documentation for every international shipment, including the commercial invoice, packing list and available product or compliance documents. Before dispatch, our logistics team confirms the consignee details, declared value, shipping terms and destination requirements with you. Tracking information is provided after shipment, helping your team prepare for import clearance with confidence.
Documents checked before dispatch · Shipment details confirmed · Global tracking provided
Payment
Payment is by bank wire only in RMB/CNY, GBP, EUR or USD. Amikon does not accept credit cards or provide credit terms. Cleared payment is required before shipment unless the written quotation expressly states otherwise.
Product Condition
Factory New These are new and current items that are procured directly from the manufacturer.
New In Sealed Package Parts are new. They have not been used and still have their original package seal intact.
New in Original Package These parts are new. The packages were not originally sealed by their original manufacturer.
Quantity
Mobile *
Country/Region *
E-mail *
Company
Content *
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Amikong please read our privacy policy.
  • 20+

    years in automation
  • ISO 9001

    certified quality system
  • 12 months

    amikon warranty
  • 2-hour reply

    from your account manager
  • Success Story

    solutions in action
PRODUCT DESCRIPTION

General purpose equipment monitor

Bently Nevada 1900/65A-01-00-03-00-00 is a general-purpose equipment monitor. The monitor evaluates transducer and temperature channels and applies configured alarm and relay logic. It supports general-purpose equipment monitoring without requiring a complete 3500 rack. Correct sensor configuration, external supply selection and the ordered communication option determine the installed system functions.

This order selects an external AC supply, no display, and a fiberglass weatherproof housing with a window. Approval and Modbus options are not selected. The monitor itself uses 18 to 36 Vdc; do not connect mains voltage directly to its DC input.
ACTUAL APPLICATIONS

Where 1900/65A-01-00-03-00-00 Fits Across Industrial Application Areas

Industrial uses span production and utility equipment, subject to verified product compatibility, installation requirements and operating conditions.
  • 01 · WATER & WASTEWATER

    Municipal Wastewater Collection and Treatment

    Sewage lift pumps serving municipal wastewater collection and treatment.Aeration blowers and sludge equipment in wastewater treatment plants.
  • 02 · POWER GENERATION

    Electricity Generation and Power Plant Utilities

    Gas and steam turbine generators in thermal power plants.Hydroelectric turbines and generators in conventional hydropower generating stations.
  • 03 · OIL & GAS

    Oil Production, Gas Processing and Petroleum Refining

    Turbines and compressors serving liquefied natural gas production facilities.Refinery compressors and process pumps serving downstream petroleum production.

Technical specifications for 1900/65A-01-00-03-00-00

  • Product Model
    1900/65A-01-00-03-00-00
  • Product Parameters
    General purpose equipment monitor
  • In stock
    2 units
  • Manufacturer
    Bently Nevada
  • Selected power option
    110-220 Vac, 50-60 Hz, external supply
  • Selected display
    No display
  • Selected mounting
    Fiberglass NEMA 4X/IP66 weatherproof housing with window
  • Approval and communications options
    No agency approval or Modbus option selected
  • Input channel allocation
    Four transducer inputs plus four temperature inputs
  • Temperature input selection
    Two/three-wire RTD or E/J/K/T thermocouple
  • Monitor DC input
    18-36 Vdc
  • Typical power consumption
    8.5 W; 14 W maximum
  • Relay outputs
    Six independently configured SPDT relays
  • Recorder outputs
    Four configurable 4-20 mA outputs
  • Recorder loop load
    600 ohm maximum at 18-36 Vdc loop supply
  • Configuration storage
    Nonvolatile memory; file transfer through Ethernet
  • Operating temperature
    -20 to +70 deg C
View all additional

Alternative Names

1900/65A 01 00 03 00 00 1900/65A-01-00-03-00-00 general-purpose equipment monitor Bently Nevada 1900/65A-01-00-03-00-00
SYSTEM & REPLACEMENT CHECK

Information needed before ordering

Three direct checks to secure your system integration and minimize ordering risks.

Information

System integration Replacement check Manuals & support
GENERAL PURPOSE EQUIPMENT MONITOR

Integrating 1900/65A-01-00-03-00-00

The monitor evaluates transducer and temperature channels and applies configured alarm and relay logic. It supports general-purpose equipment monitoring without requiring a complete 3500 rack. Correct sensor configuration, external supply selection and the ordered communication option determine the installed system functions.
Configure the four transducer channels for their supported input type and the four temperature channels for the installed RTD or thermocouple. This order does not select Modbus. The separate 1900/01 communications upgrade is documented, but it is not presumed installed.
Use the selected external AC-to-DC supply and weatherproof housing, verifying field wiring and sensor configuration against user guide 173400 and wiring diagrams 173089. The monitor is not installed in a Division 1 area simply because an approved sensor can be connected through barriers.

Features:

  • Match exact spare identity, complete installed system and installation instructions
  • Follow the applicable installation instructions
  • Confirm unverified configuration details
The 1900/65A-01-00-03-00-00 general-purpose equipment monitor requires appropriate configuration before system integration and commissioning.
INTERCHANGEABILITY

Verify the complete replacement identity before commissioning

Replacement of 1900/65A-01-00-03-00-00 requires comparing exact spare identity, complete installed system and installation instructions. A shared base family or similar appearance does not establish a drop-in replacement for the complete ordered assembly.
Configure the four transducer channels for their supported input type and the four temperature channels for the installed RTD or thermocouple. This order does not select Modbus. The separate 1900/01 communications upgrade is documented, but it is not presumed installed.
No verified exact-order discontinuation date, product revision or designated successor is asserted. Document revisions identify the reference literature, not hardware changes to the supplied product. Unconfirmed replacement options must be resolved before substitution.

Features:

  • Preserve the complete ordering identity
  • Compare the installed electrical and mechanical interfaces
  • Do not infer hardware revisions or successor models
The 1900/65A-01-00-03-00-00 general-purpose equipment monitor requires replacement verification against the complete installed configuration and current manufacturer documentation.
DOCUMENTATION STATUS

Browse the Manuals, Datasheets, Official Documents, Links

Important Notice: No verified product PDF is currently available on this page. Amikong-hosted reference documents will be listed only after their product identity and scope have been checked. Consult the applicable manufacturer instructions before use; additional documents are included only when expressly listed in the quotation.

Features:

  • Verify document identity before procurement or installation
  • Match the complete order to the manufacturer document scope
  • Accessories are supplied only when listed in the quotation
Documentation for the 1900/65A-01-00-03-00-00 general-purpose equipment monitor must be checked for document applicability before installation or commissioning.

Important notice

Manuals, software, firmware, cables, calibration data and accessories are included only when listed in the quotation. AMIKON is an independent supplier and is not affiliated with or authorised by the manufacturer.
This content has been produced using multiple sources. Takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
BUYER INFORMATION

Commercial terms without hidden steps

Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • 01

    Shipping & delivery

    Dispatch
    Eligible stock: same / next day
    Carriers
    DHL, FedEx or UPS
    Ship from
    Xiamen, China
    Packed size
    19.8x16.2x10.8cm
    Shipping weight
    1.35 kg
  • 02

    Payment & customs

    Payment
    Bank transfer (T/T)
    Currencies
    USD · EUR · GBP · RMB
    Credit cards
    Not accepted
    HS reference
    9031809090
    Origin
    USA
  • 03

    Warranty & returns

    Warranty
    12 months from AMIKON
    Inspection
    Label, condition and packing checks
    Returns
    Prior RMA authorisation required
    Compatibility
    Confirm before order
    OEM warranty
    Does not apply
Your written quote confirms the product identity, price, availability, lead time, warranty and shipping terms before payment.
  • Part checked

    Full suffix recorded
  • Condition checked

    Label and appearance
  • Packing checked

    Antistatic protection
  • Tracking supplied

    Established couriers
  • Sandy Lin

    Dedicated account manager · 15+ years
FREQUENTLY ASKED QUESTIONS

Questions buyers ask about 1900/65A-01-00-03-00-00

Direct answers about identity, compatibility, stock, warranty, payment and shipping.
  • What does 1900/65A-01-00-03-00-00 identify?

    This order selects an external AC supply, no display, and a fiberglass weatherproof housing with a window. Approval and Modbus options are not selected. The monitor itself uses 18 to 36 Vdc; do not connect mains voltage directly to its DC input.
  • What is the function of this component?

    The monitor evaluates transducer and temperature channels and applies configured alarm and relay logic. It supports general-purpose equipment monitoring without requiring a complete 3500 rack. Correct sensor configuration, external supply selection and the ordered communication option determine the installed system functions.
  • Which equipment is compatible?

    Configure the four transducer channels for their supported input type and the four temperature channels for the installed RTD or thermocouple. This order does not select Modbus. The separate 1900/01 communications upgrade is documented, but it is not presumed installed.
  • Where is this component used?

    The manufacturer describes configurable transducer channels for general-purpose equipment monitoring. Channel values and status conditions can drive selected relay logic within the complete installation.
  • What matters during installation?

    Use the selected external AC-to-DC supply and weatherproof housing, verifying field wiring and sensor configuration against user guide 173400 and wiring diagrams 173089. The monitor is not installed in a Division 1 area simply because an approved sensor can be connected through barriers.
  • Can the built-in Ethernet port prove Modbus is enabled?

    No. Ethernet is used for configuration, while Modbus is a separately selected communications option. This complete order ends in 00, indicating no Modbus option.
  • Can Reset clear an alarm whose cause still exists?

    No. Reset clears latched statuses and relays when the condition driving the status no longer exists. Resolve the underlying condition and follow the configured latching behaviour.
READY TO VERIFY YOUR PART?

Get a 1900/65A-01-00-03-00-00 quote with price, lead time and revision check.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: Amikon Limited sells new and surplus products and develops channels for purchasing such products. Amikon Limited is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Amikon Limited is not an authorized distributor of this product, the Original Manufacturer's warranty does not apply. Amikon Limited is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.