Fieldbus Communication Interface
CI810B AF100 Fieldbus Communication Interface
2*AF100 Twisted Pair Modems.
Including:
1 pce Power Supply Connector 3BSC840098R1
1 pce TB807 Modulebus Terminator 3BSE008538R1
2 pcs Terminal Blocks 3BSC840098R1
The basic system software version 1.5 loaded.
AF100 Connector 3BSC840105R1
Processor module
AC500-eCo Processor module
Memory 4MB
12 DI 24 VDC. 6 DO-Relay
2 DC 24 VDC
Ethernet interface
3 option slots
LV AC industrial single drive module
ACS880-04 drives
3AXD10000497831
LV AC industrial single drive module
IEC: Pn 500 kW, 715 A, 500 V
UL: Pld 600 Hp, 705 A, 460 V
Number of Phases:3-phase
Enclosure Type NEMA:Open Type
Operating Humidity (RHamb):5 ... 95
Sound dB (A):72 dB(A
Frequency (f): 47.5 ... 63 Hz
Frame Size: R11
Input Voltage (Uin):380 ... 500 V
LV AC servo drive
MotiFlex e180
MFE180-04AN-05A0-4+L518+N8020
3P, 380 VAC
IN: 5 A, HALL incremental encode
A free Mint programming license
easy positioning tasks
drive supports various feedback types
Drive Module
DRIVE
INPUT: 179-19.8 AMP 3 PHASE 380-480 VAC 48-63 HZ
OUTPUT: 15.5-18 AMP 0-280-480 VAC 0-500 HZ
7.5 KW / 10 HP
IP20
(3AUA0000014470)
LV AC machinery drive module
LV AC machinery drive module
IEC: Pn 3 kW, 8 A, 400 V
UL: Pld 5 Hp, 7.6 A, 480 V
(ACS880-M04-08A0-5)
Number of Phases:3-phase
Degree of Protection:IP20
Enclosure Type NEMA:Open Type
Altitude:1000 m
Operating Humidity (RHamb):5 ... 9
Power Factor:0.98
Sound dB (A):47 dB(A)
Inverter module
Output Power: 1.1 kW
Output Voltage: 380–480 V AC, 3-phase ±10%
Continuous current: 4.5 A (at 40°C)
Dynamic peak current: Up to 7.0 A
Input Voltage: 3-phase 380–480 V AC
Input Current (Typ.): 4.6 A @ 480 V AC
CONTROL UNIT
Supply Voltage: 24 V DC
Power Consumption: ≤ 5 W
Isolation Voltage: 500 V AC
Voltage range: 0–30 V DC
Logic thresholds: ≤ 5 V DC
Ethernet/IP: TCP/IP, IPv4,
CONTROL UNIT
ACH580
CCU-24-H+N2000 AHVK4.
ACH580 drive systems
Temperature: -20°C to +55°C (full function)
Humidity: 5–95% non-condensing
Safety functions module
Supply Voltage: 20–29 VDC
Power Consumption: 8 W (max)
Response Time: ≤15 ms
Isolation: 2500 VAC
Operating Temperature: -25°C to +60°C
CHARGING CONTROL BOARD
AC Input: 380–480 VAC
DC Input:500–750 VDC
Output Charging Voltage: 24/48/110 VDC
Range: 10–50 A
Current Accuracy: ±1%
Efficiency: ≥92% under full load
Full performance: -10°C to +50°C
Humidity: ≤95% RH (non-condensing)
CONTROL UNIT
ACH580 HVAC Drives
ACH580-31-CCU-24-H+N2000-AHVK4
I/O Expansion:24 VDC
Power Supply:±5% 24 VDC tolerance
Temperature Range: -15°C to +50°C (non-condensing).
Humidity: ≤95% RH.
GATE DRIVER BOARD
3AXD50000049025
GATE DRIVER BOARD
BGDR-01C
MODEL: ACS880-04
4 X CONNECTORS
REPLACED PART# 3AUA0000074145
Control Board
Remote Keypad Mount Kit
Interface Option
Keypad Power Supply:24 VDC
Max Cable Length: ≤ 10 m
Operating Temperature: -25°C to +55°C
Humidity: ≤ 95% RH
CHARGING CONTROL BOARD
RS-485 or CAN Bus
Modbus RTU/TCP compatibility
Overvoltage/Undervoltage Protection
Overcurrent Protection
Short-Circuit Protection
Temperature Monitoring with automatic derating
Controller Module
Clock Speed: 800 MHz – 1.5 GHz
RAM: 2 GB DDR4
Operating Voltage: 24 V DC
Power Consumption: ≤18 W
Isolation: ≥3000 V AC
Ethernet Interfaces:2× Gigabit ports
Discrete I/O: 12–24 V DC
Analog Interfaces: 4–8 channels
Motherboard
Input Voltage: 24 V DC
Backplane Power: 5 V DC
RAM Slots: 2× DDR4 SO-DIMM
Storage: Integrated 16 GB flash
Operating: -40°C to +70°C
Humidity: 5–95% non-condensing
MTBF: >250,000 hours
Processor Module
Operating Voltage: 24 V DC
Power Consumption: <12 W
Input Protection:±40 V peak transient
Digital I/O: 16 channels
Analog I/O (Optional): 4 channels
Ethernet: 2× 10/100 Mbps ports
Serial: RS-232/RS-485 for legacy devices
Fieldbus: PROFIBUS DP
Control Board
Operating Voltage: 24 V DC
Power Consumption: ≤15 W
Voltage Range: 0–10 V DC
Resolution: 12-bit
Channels: ≥8 opto-isolated
Input Signal Level: 24 V DC
ADAPTER BOARD
Electrical Rating:24V DC (±10%)
Compatibility:ACS880-04
Communication Ports:RS485
Operation: 0°C to +55°C