Esacontrol Board
SEAM E08002
DISCONTINUED BY MANUFACTURER
Esacontrol Board
INFI 90
5 VA
+5
+15 VDC
PLANT COMMUNICATION CBLE
NKCL01-100
Coax INFI-Net Comm Link - 100 Ft (Pvc)
Connect NTCL to NTCL, Must use with NKTL01
15240 mm
Flash Drive
Model: 3HAC16917-1/00
Type: Flash Drive
Capacity: 64GB
Interface: USB
Temperature Range: -20°C to 70°C
Backplane Board
Model: DSQC 501
Part Number: 3HAC3617-1
Type:Backplane Board
Input Voltage: Typically 24V DC
Operating Temperature: Typically 0°C to 50°C.
Storage Temperature: -20°C to 70°C.
Humidity: Up to 95% RH (non-condensing)
Digital I/O Relay Board
Model: DSQC 328
Part Number: 3HAB7229-1
Type:Digital I/O Relay Board
Input Voltage:24V DC
Storage Temperature: -20°C to 70°C.
Input Voltage: Typically 24V DC
Power Consumption: Typically around 15-30W
Current Rating: Typically 1A at 24V DC
Humidity: Up to 95% RH (non-condensing)
Axis Computer Board
Model: DSQC503A
Part Number: 3HAC18159-1
Type: Axis Computer Board
Operating Temperature: Typically 0°C to 50°C.
Storage Temperature: -20°C to 70°C.
Input Voltage: Typically 24V DC
Power Consumption: Typically around 15-30W
Current Rating: Typically 1A at 24V DC
Humidity: Up to 95% RH (non-condensing)
CONNECTION BOARD
Model: DSQC504
Part Number: 3HAC5689-1/03
Type: CONNECTION BOARD
Operating Temperature: Typically 0°C to 50°C.
Storage Temperature: -20°C to 70°C.
Humidity: Up to 95% RH (non-condensing).
Bus cable
Model Number: 3HAC5518-1 DB15 1239
Cable Type: Bus cable for communication between ABB automation systems or equipment
Connector Type: DB15 (15-pin D-sub) connectors on both ends
Cable Length: Typically available in various lengths, common configurations include 1 meter, 2 meters, 3 meters, etc.
DIN Rail Ruggedized Ethernet Switch
DIN Rail mounted managed Ethernet switch (wall mounting possible)
Metal housing
Up to 10 ports (electrical, optical or SFP cages)
Up to 3 GbE ports (electrical, SFP or Combo ports)
Multimode and Single Mode versions available
Huge variety on optical ports (e.g. SFP cages, SC, ST)
SFP’s in various versions available (MM, SM, single fibre)
Low voltage (18 - 60 VDC) or high voltage (48 - 320 VDC, 90 - 265 VAC) power supply
Redundant power supply possible
Typical power consumption: 12 - 21 W
Control Module
Part Number: UNS0118A-Z
Type: Control Module
Voltage: 24V DC
Operating Temperature: Typically -20°C to +60°C
Storage Temperature: -40°C to +85°C
Control Power
- Space-saving design and small footprint
- Rated supply voltage range from 100-240 V AC / 100-250 V DC
- Rated output voltage 24 V DC
- Rated output current of 3.0 A, 5.0 A, 10.0 A, 20.0 A and 40.0 A
- High efficiency of up to 94 %
- Power reserve design of 150 % for 5 s to start heavy loads
- Output voltage adjustable via front-face rotary potentiometer “OUTPUT Adjust”, 24-28 V
- Low power dissipation and low heating
- Free convection cooling (no forced cooling)
- Coated PCBAs
Control Processor Module
Harmony-07
Control Processor Module
High-performance processing unit for real-time control and data processing
Supports industrial communication protocols such as Modbus, Profibus, Ethernet/IP
24V DC
-20°C to +60°C
PBA to HN800 Cable
SPK800-PBA1-01
Cable
1.0 Meter
PBA800 interface
HN800 device interface
Supports TER8x0 terminator to redundant PBA800 adapters for connection
Digital signal transmission
Power Entry Panel Dual Chassis
PHARPSPEP21013
Power Entry Panel
Dual Chassis Design
Typically supports AC or DC input, depending on the application
Appropriate current based on load requirements