SENSOR CONDITIONING
TELEPERM XP MODULE FUM 210
FOR SENSOR CONDITIONING FAST BINARY SIGNAL ACQUISITION,
OR DRIVE CONTROL SENSOR, MONITORING AND SIGNAL.
MODULE CONDITIONING:
14 CHANGEOVER OR 28 SINGLE CONTACTS
WITH SENSOR SUPPLY AND MONITORING,
28 BINARY INPUTS WITHOUT SENSOR SUPPLY
Symphony Plus I/O Open Loop Control Card
Migration of Contronic P, E, 3 to System 800xA with AC 870P
Migration of Maestro UX Operations
Maestro UX and System 800xA Operations in parallel
Evolution of SymBatch to 800xA Batch Management
BINARY SIGNAL COUPLING MODULE
TELEPERM XP MODULE FUM 211,
BINARY SIGNAL COUPLING MODULE
16 BINARY INPUTS
WITE ELECTRICAL ISOLATION
VIA OCTOCOUPLERS 16 BINARY
OUTPUTS 250 MA (WITH LIMITATION)
STEADY OR FLASHING (8, 2, 0,5 HZ)
SUITABLE TO CONNECT CONSOLE CONTROL TILES.
CAPABLE FOR 2 DESK TILES USE IN SPPA-T200
SENSOR CONDITIONING
TELEPERM XP MODULE FUM 210
SENSOR CONDITIONING FAST BINARY SIGNAL ACQUISITION,
OR DRIVE CONTROL SENSOR,
MONITORING AND SIGNAL. MODULE CONDITIONING:
14 CHANGEOVER OR 28 SINGLE CONTACTS
WITH SENSOR SUPPLY AND MONITORING,
28 BINARY INPUTS WITHOUT SENSOR SUPPLY
INPUT MODULE
INPUT MODULE
32POINT
LOGIC
SERIES 90-30
POSITIVE/NEGATIVE
7 AMP MAX
24 VDC
OUTPUT MODULE
IC693ALG390
OUTPUT MODULE
ANALOG
90-30 SERIES
2 CHANNEL
24 VDC 5 MA
120 MA
SCREW TYPE TERMINAL
CPU ENERGY PACK MODULE
IC695ACC400
CPU ENERGY PACK MODULE
INTENDED FOR USE WITH RX3I CPE305 OR CPE310 CONTROLLER CPU
I/O MODULE
IC693MDL930
I/O MODULE
DISCRETE
8 POINT
AC/DC OUTPUT
120/240 VAC
5/24/125 VDC
RELAY
NORMALLY OPEN
4 AMP
ISOLATED
8 CHANNEL RELAY OUTPUT MODULE
90-30 SERIES
ANALOG INPUT MODULE
IC695ALG600
ANALOG INPUT MODULE
UNIVERSAL
CONFIGURABLE FOR THERMOCOUPLE
RTD
RESISTIVE
CURRENT OR VOLTAGE
8 CHANNEL GENERAL PURPOSE
2 ISOLATED GROUPS: 4 CHANNELS PER GROUP
2CJC CHANNELS
COLD JUNTION COMPENSATION
OUTPUT MODULE
OUTPUT MODULE
12/24 VDC
POSITIVE LOGIC
32 POINTS
INTERFACE USES FUJITSU CONNECTOR
CENTRAL PROCESSING UNIT
CENTRAL PROCESSING UNIT
300 MHZ
10 MB MEMORY
2 SERIAL PORTS
2 SLOT
CONTROL MODULE
CONTROL MODULE
RX3I CPU
1 GHZ PROCESSOR
2 SERIAL PORTS
RS-485 / RS-232
20 MB USER MEMORY
DP/AS-i Link Advanced
SIMATIC NET,
DP/AS-INTERFACE LINK ADVANCED;
GATEWAY PROFIBUS
DP/AS-INTERFACE WITH MASTER PROFILE M3, M4 ACC.
TO EXTENDED AS-I SPEC.
V3.0 FOR INTEGRATION IN PROFIBUS DP;
DOUBLE MASTER WITH DISPLAY;
DEGREE OF PROTECTION IP20.
Standard Operator Terminal
18…32V DC (24V DC nom)
Panelview 300
24 Volts DC
240 KB
PanelView 300 Standard Operator Terminals
Monochrome transflective LCD with LED backlight
Universal Variable Speed AC Drive
10 HP/7.5 KW 380V to
Inverter 380
480V ±10%
3PH 9.5A
Position control/Digital lock
Programmable logic functions
Two programmable thresholds
Mains dip ride through
Frequency slaving
Catch a spinning motor
Eight preset speeds/accelerations/decelerations