8mm Eddy Current Sensor
Linear Measurement Range 2 mm (80 mils)
Initial Air Gap 0.5 mm (20 mils)
Incremental Scale Factor (ISF)
ISO: 8 V/mm (203.2 mV/mil) ± 5%@
temperature range 0 to 45°C(+32 to +113°F)
Deviation from best fit straight line(DSL)
± 0.025 mm (± 1 mil)@
temperature range 0 to 45°C(+32 to +113°F)
Minimum Shaft Diameter 25 mm (0.79”)
mm Eddy Current Sensor
Linear Measurement Range 2 mm (80 mils)
Initial Air Gap 0.5 mm (20 mils)
Incremental Scale Factor (ISF)
ISO: 8 V/mm (203.2 mV/mil) ± 5%@
temperature range 0 to 45°C(+32 to +113°F)
Deviation from best fit straight line(DSL)
± 0.025 mm (± 1 mil)@
temperature range 0 to 45°C(+32 to +113°F)
Minimum Shaft Diameter 25 mm (0.79”)
Eddy Current Displacement Sensor
Operating temperature range: 0...+ 100°C
Operating frequency range: 0...15 kHz (-3dB)
Displacement measuring range: 2,15 mm
Sensitivity: 7,87 V/mm (200 mV/mil)
Mean voltage: -10,00 V
Power supply: -24 V nominal
Standard cable: 4 - core (4 x 0,2 mm2)
Monitoring Module
Category: Power Module
Voltage: 24V
Current: 100-400A
Operating Temperature: 50°C
Maximum Temperature: 70°C
Frequency Range: 47-63HZ
Accuracy: 1%
Eddy Current Sensor
2 V/mm ≤ ±1.5% max
Approx. 5.5 mm
±4.0 mm
2,500 m/s
-35 to 175°C
200°C
-0.3%/100°K Zero Point