Velomitor CT Velocity Transducer
1 2 Plate Stud 3/8-in 24 to M8x1
0 0 MIL-C-5015 connection interface
0 1 through0 4CSA/NRTL/C (Class I, Division 1)
ATEX/IECEx/CSA (Class I, Zone0/1)
Velomitor Piezo-velocity Sensors
01 1/2 - 20 UNF
Sensitivity:3.94mV/mm/s (100 mV/in/s)±5%
Velocity Range:1270 mm/s (50 in/s) peak.
TransverseSensitivity:Less than 5% of sensitivity.
AmplitudeLinearity:±2% to 152 mm/s (6 in/s)peak.
OperatingTemperatureRange:
-55°C to 121°C(-67°F to 250°F)
ControlLogix Discrete output module
Outputs:16-Points
Module Type:Digital AC Output Module
Voltage:120-140 Volts AC
No. of Outputs Sixteen (16) mechanically fused
Voltage Category:120 / 240 Volts AC
Operating Voltage Range:74-265 Volts AC
Backplane Current at 5 Volts:400 mA
Generic Servo Interface Module
Series:ControlLogix
Module Type:Generic Servo Interface Module
Axes per Module:8
Axes per Controller:32
Backplane Current (5Volts):760 milliamps
Backplane Current (24Volts):2.5 milliamps
Power Dissipation:6.2 Watts
SERCOS Data Rate:4 or 8 Megabits-Second
Current Draw (5.1 Volts):1.2 amps
Thermal Dissipation:21.2 BTU-hour
Isolation Voltage:50 Volts Continuous
SINGLE MOTOR MODULE
SINAMICS S120
SINGLE MOTOR MODULES
INPUT: 600 V DC
OUTPUT: 3-PH 400 V,
210 A FRAME SIZE: CHASSIS
INTERNAL AIR COOLING SUPPORT
OF THE EXTENDED SAFETY
INTEGRATED FUNCTIONS
INCL. DRIVE-CLIQ CABLE
power block
SINAMICS
replacement power block
for 510-750 V DC
380 A Motor Module
3 phases painted modules
and nickel-plated busbars
ACTIVE LINE MODULE
SINAMICS S120
ACTIVE LINE MODULE
INPUT: 3-PH380-480V, 50/60HZ
OUTPUT: 600 V DC, 549 A,
300KW
INTERNAL AIR COOLING INCL
DRIVE-CLIQCABLE
MPC4 machinery protection card
Number of inputs : 4 per MPC4 card
DC range : 0 to +20 V or 0 to −20 V
AC range : ±10 V max.
Common mode voltage range : −50 to +50 VC
MRR : >60 dB at 50 Hz
Crosstalk : −72 dB
Input impedance : 200 kΩ
DC signals : 0 to 25 mA
AC signals : ±8 mA max
4 Channel Relay Output Module
Channel-to-Channel: 1500 VAC
Field-to-System: Reinforced isolation :2500 VAC
Per Channel: 1–2 W
Total: ≤ 8 W
Operating Temperature: -40°C to +70°C (industrial-grade)
Storage Temperature: -50°C to +85°C
Humidity: 0–95% (non-condensing)
SINAMICS Control unit
The Power Module:DC 24 V
External power supply:DC 20 ... 29 V
Max. power consumption:2.00 A
Power loss 12.00 W
Number:2
Output (resistive load):DC 30 V, 0.5 A
Number 15
Switching level: 0→1 11 V
Switching level: 1→0 5 V
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:205 Amps, 110kW ND, 90kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:205 Amps, 110kW ND, 90kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:170 Amps, 90kW ND, 75kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:170 Amps, 90kW ND, 75kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
M jumper installed (preferred)
Dynamic Braking:DB Transistor
HIM Blank (No HIM)
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:140 Amps, 75kW ND, 55kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:140 Amps, 75kW ND, 55kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:None
Control panel
Type: LCD or TFT color touchscreen
Operating Voltage: 24 VDC (±10%) or 110–230 VAC
Power Consumption: 10–20 W
Operating Temperature: -10°C to +55°C
Storage Temperature: -40°C to +70°C
Humidity: 5–95% (non-condensing)
FIRING PULSE TRANSFORMER BOARD
Model: SDCS-PIN-H41
Part Number: 3ADT320600R1501
Pulse Voltage: 5–24 V DC
Isolated Pulse Voltage: Typically 10–30 V
Output Current: 1–2 A
Primary-to-Secondary Isolation: ≥2500 V AC
Insulation Resistance: >100 MΩ
Armor ControlLogix Controller
Series:ControlLogix
Module Type:Armor ControlLogix Controller
Standard Memory:4 Megabytes
I/O Memory:0.98 Megabytes
Max Total I/O:128,000
Max Analog I/O:4000
Max Digital I/O:128,000
Ethernet Ports:4 Ethernet M12 Category 5E
USB Ports:USB 1.1 Full Speed (12 Mbps)
Nom Input Voltage:24 Volts DC
Input Voltage Range:18-32 Volts DC
Digital Input Module
Series:ControlLogix
Module Type:Isolated Digital Input Module
Inputs:16 Individually Isolated Inputs
Input Voltage:240 Volts AC
Operating Voltage Range:159-265 Volts AC
Input Delay Time:Programmable 9 or 18 milliseconds
ControlLogix Lithium Battery Assembly
Series:ControlLogix
Battery Type:Externally Mounted
Power Dissipation (Max):4.5 Watts
Mounting:Horizontal
Enclosure:Open
Backplane Current (5 Volts DC):10 amps
Backplane Current (24 Volts DC):2.8 Amps
DC Output Module
Series:ControlLogix
Module Type:Electronic Fused DC Output Module
Outputs:16-Point Electronically Fused
Voltage:12-24 Volts DC
Operating Voltage Range:10-30 Volts DC
Backplane Current at 5 Volts:250 milliamps
ControlLogix Diagnostic DC Output Module
Series:ControlLogix
Module Type:Diagnostic DC Output Module
Outputs:16-Point Diagnostic
Voltage:24 Volts DC Source
Operating Voltage Range:19.2-30 Volts DC
Maximum Output Current Rating-Point:2 Amps at
Power Dissipation (Max):3.3 Watts at 60 Celsius
ControlLogix Processor Module
Series:ControlLogix
Module Type:Processor Module
I-O Memory:0.98 MB
User Memory:8 MB
Maximum I-O:128,000
Maximum Analog I-O:4,000
Maximum Digital I-O:128,000