Honeywell

Chassis for non-redundant I/O modules (conformal coated)

Honeywell

Safe digital output module (24 Vdc, 0.55 A, 8 channels) (conformal coated)

Honeywell

Honeywell

Safe high-density analog input module (24 Vdc, 16 channels) (conformal coated)

Honeywell

Controller I/O Termination Assembly

Typically 24V DC or 12V DC
Output Type Source 
Load Voltage 15 30 VDC Maximum
On-State Voltage 24 V (typ), load current @ 0.5A
Off-State Leak Current 5.0 µA (max)
Turn-On/Turn-Off Time 10 ms (max)

Honeywell

Honeywell

Honeywell

SYSTEM INTERCONNECTION CABLE TERM.ON FTA

Honeywell

Honeywell

Honeywell

Honeywell

Honeywell

Analog Output Module

Output Type 4-20 mA
Output Channels 16
Output Ripple < 100 mV 
peak-to-peak at power line frequency
Output Temperature Drift 0.005% of Full Scale/°C
Output Readback Accuracy ±4% of Full Scale
Output Current Linearity ± 0.05% of Full Scale nominal.
Resolution ± 0.05% of Full Scale
Calibrated Accuracy ± 0.35% of Full Scale (25oC) including linearity
Directly Settable Output Current Range 0 mA, 2.9 mA to 21.1 mA
Maximum Output Compliant Voltage 16 V

Honeywell

Honeywell

Honeywell

Honeywell

Honeywell

Honeywell

Honeywell

High Level Analog Input Module

Inputs per module 16 
Input types V, mA
A/D Converter One per module
A/D Resolution 15 Bits
Update rate 100ms 
Long term Stability 0.1% per year
Channel Configuration Data Stored in non-volatile memory

Honeywell

Honeywell

Digital Output Module

Output Channels 32
Output Type SINK (Open Drain)
Load Voltage 15 30 VDC 
MaximumLoad Current 0.1 A per channel (Max)
Galvanic Isolation 1000 VAC RMS for System – to – 
Field isolation (user supplied field Power)
On-State Voltage 0v VDC (load current @ 0.1A max )
Off-State Voltage 24 V (typ),
Off-State Leak Current 100 µA (max)
Turn-On/Turn-Off Time 10 ms (max)

Honeywell

Honeywell

Honeywell

SERIES C CONTROL MODULE

Operating Voltage: 24 V DC
Input Current: 1.5 A
Output Power: 10 W
Output Frequency: 1 kHz
Operating Temperature: -20°C to +70°C
Humidity Range: 5% to 95% non-condensing

show:
476-500 of 1615
< page << 20 of 65 >
All product and service marks contained herein are the trademarks or service marks of their respective owners.