We carry Honeywell surplus parts. Please search through our database for the Honeywell part numbers that you require.
 
You can also go to our entire Honeywell inventory by selecting the target below.

 
Please click on the part number or image to view product details.
show:
426-450 of 1624
< page << 18 of 65 >
Honeywell

Safe Fire detector input FTA with Line Mon. (24 Vdc, 16 ch.) (conformal coated)

Honeywell

Safe Gas -Flame detector input FTA (0 - 20 mA, 16 channels) (conformal coated)

Honeywell

Safe Gas -Flame detector input FTA (0 - 20 mA, 16 channels)

Number of input channels: 16
Power requirements: 24 Vdc external, 3 mA
Input current: 0—25 mA
Input resistance: 500 Ω (± 5%)
 Output voltage 0—4 Vdc
 Accuracy 0.1%
Rating: 500 mAT (slow-acting)

Honeywell

Safe 0(4)-20 mA analog input FTA (16 channels) with HART interface

Honeywell

Safe 0(4)-20 mA analog input FTA (16 channels)

Honeywell

Safe analog input FTA (4 channels) (conformal coated)

Honeywell

Safe analog input FTA (4 channels)

Honeywell

Safe active/passive digital input FTA (115 Vac/dc, 16 ch.) (conformal coated)

Honeywell

Safe active/passive digital input FTA (115 Vac/dc, 16 ch.)

Honeywell

Current-limited digital input FTA (24 Vdc, 16 channels)

Honeywell

Safe digital output module (110 Vdc, 0.32 A, 4 channels) (conformal coated)

Honeywell

Safe digital output module (110 Vdc, 0.32 A, 4 channels)

Honeywell

Safe loop-monitored digital output module (48 Vdc, 0.5 A, 4 ch.) (conformal coated)

Honeywell

Safe loop-monitored digital output module (48 Vdc, 0.5 A, 4 ch.)

Honeywell

Safe digital output module (48 Vdc, 0.75 A, 4 channels) (conformal coated)

Honeywell

Safe digital output module (48 Vdc, 0.75 A, 4 channels)

Honeywell

Safe digital input module (48 Vdc, 16 channels) (conformal coated)

Honeywell

Safe digital input module (48 Vdc, 16 channels)

Honeywell

Safe loop-monitored digital output module (24 Vdc, 1 A, 4 ch.)

Honeywell

Safe digital output module (24 Vdc, 2 A, 4 channels) (conformal coated)

Honeywell

Safe digital output module (24 Vdc, 2 A, 4 channels)

Honeywell

Analog output module

Space requirements: 4 TE, 3 HE (= 4 HP, 3U)
Power requirements: 5 V DC, 30 mA
Number of outputchannels:2
Output specification(mA):Active or passive, 0-20 / 4-20 mA
D/A converter: 12-bit
Off current: < 0.05 mA
Maximum loadcapacitance:100 nF
WDG input current: 0.5 mA

Honeywell

Safe analog output module (0(4)-20 mA, 2 channels)

Honeywell

Safe line-monitored digital input module with earth fault monitor (16 channels) (conformal coated) (ATEX)

Honeywell

Safe line-monitored digital input module with earth fault monitor (16 channels)

show:
426-450 of 1624
< page << 18 of 65 >
All product and service marks contained herein are the trademarks or service marks of their respective owners.