special remind
The warranty of industry automation components and parts that "amikon" 1-year warranty.
Current Buffer
4-20 mA
±0.1% of full-scale value
Up to 600 Ω
<10 ms
Signal isolation
amplification
and distribution in current loop systems
Pulser
Pulser Unit
Square wave signal
5V to 24V DC
Up to 10 kHz
TTL or RS-422 compatible output
High-precision pulse generation
with ±0.1% tolerance
E/I Converter
Input Signal:1-5 V DC
(configurable depending on system requirements)
Output Signal: Standard 4-20 mA current loop
Accuracy: ±0.1% of full-scale value
Load Impedance: 0-600 Ω for current loop compatibility
Response Time: <10 ms
E/I Converter
Input Signal: 0-10 V DC
(configurable depending on system requirements)
Output Signal: Standard 4-20 mA current loop
Accuracy: ±0.1% of full-scale value
Load Impedance: 0-600 Ω for
current loop compatibility
Response Time: <10 ms
Transfer Relay Delay
Contact Configuration:
1 NO (Normally Open)
1 NC (Normally Closed)
Contact Rating:
AC: 250V AC, 10A (resistive)
DC: 24V DC, 10A (resistive)
Coil Voltage: 24V DC (Nominal)
Contact Material: Silver alloy for enhanced durability and low contact resistance
Time Delay Range: 0.1 to 10 seconds (adjustable)
Switching Time (Normal Mode): <10 ms (without delay)
Transfer Relay
AC: 250V AC, 10A
DC: 24V DC, 10A
Coil Voltage: 24V DC (Nominal)
Contact Material: Silver alloy for
low contact resistance and enhanced durability
Switching Time: <10 ms
Life Expectancy:
Mechanical Life: 10 million operations
Electrical Life: 100,000 operations at rated load
Signal Monitor
Response Time
Typically ≤ 1 ms for fast signal monitoring
Display
LED or LCD display (if applicable)
for real-time monitoring feedback
Mounting DIN rail or panel mount
Operating Temperature -20°C to +60°C
Storage Temperature -40°C to +85°C
Humidity 5% to 95% non-condensing
118VAC Auxiliary Relay
Coil Voltage 118 VAC
Contact Configuration
1 x Normally Open (NO),
1 x Normally Closed (NC) contacts
Max Switching Voltage 250 VAC, 30 VDC
Max Switching Current 8 A
Mounting Type DIN rail or panel mount
Operating Temperature Range -20°C to +60°C
Storage Temperature Range -40°C to +85°C
Humidity 5% to 95% non-condensing
24 AUX Relay
Coil Voltage 24 VDC
Contact Configuration
1 x Normally Open (NO),
1 x Normally Closed (NC) contacts
Max Switching Voltage 250 VAC, 30 VDC
Max Switching Current 8 A (resistive load)
Temperature Range -20°C to +60°C
Humidity 5% to 95% non-condensing
3-Input Auctioneer
Input Type
3 inputs,
digital or analog depending
on configuration
Input Voltage Range
24 VDC or 120/240 VAC
Mounting Type DIN rail or panel mount
Operating Temperature Range -20°C to +60°C
Storage Temperature Range -40°C to +85°C
Humidity 5% to 95% non-condensing
Square Root Extractor
24V DC or system-specific
Operating Temperature: -20°C to +60°C
Storage Temperature: -40°C to +85°C
Humidity: 5% to 95%, non-condensing
Rate Limted Follower
24V DC or system-specific
Operating Temperature: -20°C to +60°C
Storage Temperature: -40°C to +85°C
Humidity: 5% to 95%, non-condensing
Derivative
24V DC or system-specific
Operating Temperature: -20°C to +60°C
Storage Temperature: -40°C to +85°C
Humidity: 5% to 95%, non-condensing