The warranty of industry automation components and parts that "amikon" 1-year warranty.
TCB Board
Supply Voltage:24 V DC (±10%)
Grid Input:380 V AC – 575 V AC, 50/60 Hz
Pulse Frequency:50–60 Hz
Fired Thyristors:current/torque control
Operating Temperature:0°C to +55°C
afety First: Discharge DC link capacitors
Encoder Borad
SIMOVERT Master drives
Motion Control Measuring transducer
for Multiturn-encoder/Encoder SBM
Control and pre-charging Module
CONTROL AND PRE-CHARGING MODULE
PET1
WITH PHASE INTERFACE
FOR INFEED UNITS OF DESIGN E
500-575 VAC
50/60 HZ
SNUBBER RELAY BOARD
SIMOVERT MASTERDRIVES
Snubber Function :up to 1.5–2.5kV
Relay Contacts:Rated for ≥ 850A
Voltage Rating:480V AC , 50/60 Hz
Current Handling:Supporting up to 1200A systems
DRIVE BOARD
DRIVE BOARD
SIMOVERT MASTERDRIVES
MEASURING TRANSDUCER
FOR RESOLVERS WITHOUT PULSE ENCODER
INVERTER SNUBBER MODULE
Inverter snubber Module SMU3
INVERTER SNUBBER MODULE
UPPER UNIT
SMU3
SPARE PART
Allocation boar
Control Voltage: +24 V DC (±10%)
Current Consumption: ≤1.5 A
Temperature: 0–55°C ambient
Storage Humidity: ≤93% non-condensing.
Digital I/O Sourcing:10–24 V inputs, ±24 V outputs
Inverter control Module
Inverter control Module
IGD7 for devices 380-460 V 3 AC
50/60 Hz and 510-620V DC, 690
Excitation board
Input Voltage Range:380–480 V AC
Output Voltage (DC):50–250 V DC
Continuous Excitation Current: 10–20 A DC
Analog Input: Accepts ±10 V or 4–20 mA
Internal Logic Supply: Isolated 24 V DC
Temperature: 0°C to +60°C operation (-25°C storage)
Humidity: ≤96% non-condensing
DRIVE MAIN BOARD
Control Circuit: +24 V DC ±15%
Sensor Integration: 0–10 V/4–20 mA
Standard: 0°C to +55°C
Isolation Voltage: ≥ 2.3 kV
Condensation Avoidance: Operates at ≤95% humidity
DRIVE MAIN BOARD
Control Voltage: +24 V DC (±10%)
Power Handling:75–150 kW
Operating Temperature: 0°C to +55°C
Storage Temperature: -25°C to +70°C
Humidity: Up to 95%
LINE MODULE
SINAMICS / SIMODRIVE 611 BASIC
LINE FILTER FOR 55KW ACTIVE
LINE MODULE INPUT: 3AC 380-480V
50/60HZ
CONTROL MODULE
CONTROL MODULE
CLOSED-LOOP / OPEN-LOOP
CUPM
MOTION CONTROL PERFORMANCE 2
FOR SIMOVERT MASTERDRIVES
Power Interface Board
6RY18030-DA02
Power Interface Board
Input Voltage:+24 V DC
Optional Input Ranges: 10~30 V DC
Continuous (Logic/Control): 1–3 A
Rush (Reley Outputs): 5–10 A
Operating Temperature: 0°C to +55°C
Allocation board
Allocation board
C98043-A7126-L1
Control Circuit: 24 V DC ±10%
Communication: +15 V DC/-15 V DC
Screw-terminals for ≤1.5–2.5 mm² wires
Temperature: 0°C to +55°C (derating at >+40°C).
Humidity: ≤90% non-condensing
POWER INTERFACE BOARD
POWER INTERFACE BOARD
Terminals C98043-A7105-L1
SCREW CLAMP TERMINALS
W/ FUNCTIONAL SAFETY
REPLACES 6RY1803-0DA01
Power interface board
power interface
C98043-A7003-L1 incl
painted terminals
Power Side:240-690 V AC
Control Voltage: 24 V DC
Terminal Current Rating: 5–20 A
Thermal Compliance:500–600 W
Excitation board
Excitation board
power unit 15 A 4Q
C98043-A7111-L1
Continuous Output Current: 15 A
Output: 160–400 V DC
Input: Logic supply 24 V DC ±10%
Isolation: ≥2500 V AC
Temperature: 0–55°C (non-condensing)
Relative Humidity: ≤95%
Power Interface Board
AC: 120–480 V AC
DC Voltage Input: 24 V DC ±15%
Relay Outputs:10 A @ 250 V AC
Current Handling: Up to 100 A
Isolation Voltage: Up to 2.5 kV
Secondary Voltage: 12 V/24 V DC
POWER INTERFACE BOARD
POWER INTERFACE BOARD
RELAY OUTPUTS
WITH ON-BOARD TRANSFORMERS
Signal Interface:24 V DC
Number of Relays:8 to 16 channels
AC Load: 240 V AC @ 8–10 A
DC Load: 24–48 V DC @ 5-8 A