special remind
The warranty of industry automation components and parts that "amikon" 1-year warranty.
PCB BOARD
Voltage Rating: Typically
24V DC or 110V-240V AC
Operating Temperature:
Typically 0 to 70°C (32°F to 158°F)
Storage Temperature:
Generally -20°C to 70°C (-4°F to 158°F)
Humidity: Designed for
environments with 30-85% RH
Drives Interface Card
Series: ACS800 Series
Voltage :24V DC
Communication Protocols Supported:
Modbus
CANopen
Profibus DP
Ethernet/IP
Drives Interface Card
Series: ACS800 Series
Voltage :24V DC
Communication Protocols Supported:
Modbus
CANopen
Profibus DP
Ethernet/IP
INTERFACE BOARD
Input Voltage: 5 VDC (typical)
Power Consumption: ≤ 2 W
Signal Type: Digital and analog signal transmission
Operating Temperature: -20°C to +70°C (-4°F to +158°F)
Storage Temperature: -40°C to +85°C (-40°F to +185°F)
Humidity: 5% to 95% non-condensing
I/O Board
Input Voltage Range: 24 V DC
Current Consumption:
Depends on the configuration of the I/O channels
Signal Type: Digital
Input Type: 24 V DC
Output Type: Relay contacts or transistor outputs
Relay Output Rating: 30 V DC / 2 A per relay
Interface Board
Low power design
typically <10 W
Multiple I/O ports for
interfacing with sensors
actuators, and controllers
Optimized for high-speed
Interface Board
24 VDC
Low power design
typically <10 W
Multiple I/O ports for
interfacing with sensors
actuators, and controllers.
Optimized for high-speed
communication to minimize latency
PP D113 B01-25-111000: AC 800PEC
Long Description:Containing:
Slot ANYIO-1 (U4) CEX2-Bus RS422
Slot ANYIO-2 (U5) Anybus/Modbus TCP
Slot Opt. Mod.1 (U7) UF D128
Slot Opt. Mod.2 (U8) UF D128
Slot Opt. Mod.3 (U9) UF D128
Slot Opt. Mod.4 (U10) empty
Slot Opt. Mod.5 (U11) empty
COMMUNICATION UNIT
COMMUNICATION UNIT
FOR USE WITH RTU560 SERIES RACK
3 SERIAL PORTS
1 ETHERNET PORT
32 BIT CPU (INTEL 586TM)
COMPACT FLASH CARD SLOT
(560CMU02 R0001)
Feeder terminal
1A or 5A
100V (also suitable for 110V)
50 Hz / 60 Hz
250 In (peak value) dynamic,100 In for 1s,
2 Un /√3 continuous.
≤ 0.1 VA with In
CONTROL BOARD
4 channels (0-20mA, 4-20mA)
8 channels
RS-485, Ethernet, Modbus
24V DC
-20°C to +60°C
DIN Rail Ruggedized Ethernet Switch
DIN Rail mounted managed Ethernet switch (wall mounting possible)
Metal housing
Up to 10 ports (electrical, optical or SFP cages)
Up to 3 GbE ports (electrical, SFP or Combo ports)
Multimode and Single Mode versions available
Huge variety on optical ports (e.g. SFP cages, SC, ST)
SFP’s in various versions available (MM, SM, single fibre)
Low voltage (18 - 60 VDC) or high voltage (48 - 320 VDC, 90 - 265 VAC) power supply
Redundant power supply possible
Typical power consumption: 12 - 21 W
Control Power
- Space-saving design and small footprint
- Rated supply voltage range from 100-240 V AC / 100-250 V DC
- Rated output voltage 24 V DC
- Rated output current of 3.0 A, 5.0 A, 10.0 A, 20.0 A and 40.0 A
- High efficiency of up to 94 %
- Power reserve design of 150 % for 5 s to start heavy loads
- Output voltage adjustable via front-face rotary potentiometer “OUTPUT Adjust”, 24-28 V
- Low power dissipation and low heating
- Free convection cooling (no forced cooling)
- Coated PCBAs
R2 TO R6 STO SAFE TORQUE METAL BOX
R2 TO R6 STO SAFE TORQUE METAL BOX+CABLE; OPTIONS KIT
R2 TO R6 STO SAFE TORQUE METAL BOX+CABLE
OPTIONS KIT
Spare_Parts
INVERTER TRIGGER DRIVER BOARD
Input Voltage: 24 V DC
Operating Temperature: -10°C to +70°C.
Storage Temperature: -25°C to +85°C.
Humidity: 5% to 95% non-condensing.
POWER SUPPLY BOARD
Acs880/580 Series Inverter
Input Voltage: 1-phase/3-phase input
AC Input: 200–500 VAC
DC Input: 500–700 VDC
Frequency: 50/60 Hz
Output Power: ≤ 100 W
Output Voltage: Supplies +24 VDC
Load Capacity: 5 A @ 24 VDC
Procontrol System Coupling Module
Voltage: 24 VDC (±15%) or 110–240 VAC
Power Consumption: 5–10 W
Operating Temperature: -20°C to +60°C.
Humidity: 5–95% non-condensing.
IGBT Kit
Module Type:High-capacity IGBT Kit
Configuration: Dual-switch structure
Voltage Rating: 3300V/4500V
Current Rating: 1600A-3000A
Switching Speed:<150ns turn-off time
Power Class: ≥5MW