special remind
The warranty of industry automation components and parts that "amikon" 1-year warranty.
3300 XL 8 mm Probe
3300 XL 8 mm Probe
M10 x 1 thread
without armor
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
00 Not required
Length configurations:
Maximum unthreaded length: 230 mm
Minimum unthreaded length: 0 mm
Example: 0 6 = 60 mm
3300 XL 8 mm Probe
3/8-24 UNFthread
without armor
Length configurations:
Maximum unthreaded length: 8.8 in.
Minimum unthreaded length: 0.0 in.
10 1.0 meter (3.3 feet)
Example: 0 4 = 0.4 in.
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
NSv Proximitor Sensor
3300 NSv Probe
3/8-24 UNF thread
withoutarmor
5.0 metre (16.4 feet) systemlength
panel mount
0 0 Not required
NSv Proximity Sensor
7.0 5.9 ± 0.9
Extension cabledc resistance
Center conductor: 0.220Ω/m (0.067 Ω/ft)
RecommendedGap Setting 1.0 mm (40 mils)
IncrementalScale Factor 7.87 V/mm (200 mV/mil)
OperatingTemperature-52°C to +177°C
StorageTemperature-52°C to +177°C (-62°F to+351°F)
Proximitor Probe
Unthreaded Length Option : 00 = 00mm
Overall Case Length Option : 03 = 30mm
Total Length Option : 05 = 0.5 metre (1.6 feet)
Connector and Cable-Type Option : 02 = Miniature coaxial ClickLocTM connector, standard cable
Velomitor Piezo-velocity Sensors
3.94mV/mm/s ±5%.
4.5 Hz to 5 kHz ±3.0 dB
6.0 Hz to 2.5 kHz ±0.9 dB
305 m (1,000 ft)
Mounting Thread Adapter Option : 01 = 1/2 - 20 UNF
Agency Approval Option : 00 = Not required
Connector : 2-pin Mil-C-5015 hermeticallysealed,
316L stainless steel shell.
Case Material : 316L stainless steel.
VIBRATION SENSOR
Vibration Sensor
Output Type 4-20 mA
Velocity Measurement Range 0.1 mm/s to 200 mm/s
Sensitivity 1000 Hz
Mounting Thread 5/8-18 UNS-2A
Operating Temperature Range -40°C to 120°C
3300 XL 8 mm Proximity Probes
Proximity Probe
± 8 mm (0.315 inches)
Typically up to 10 kHz
Approximately 10-50 mV/mm
Typically up to 3 meters
5/8-18 UNS-2A for easy installation
Typically from -40°C to +120°C
3300 XL Standard Extension Cable
Standard Extension Cable
Cable Length 5 meters
Typically from -40°C to +120°C
Mounting Thread 5/8-18 UNS-2A
Sensing Range ± 8 mm
3300 XL 8 mm Probe
Type Proximity Probe
Sensing Range ± 8 mm (0.315 inches)
Sensing Technology Eddy current technology
Sensitivity Approximately 10-50 mV/mm
Customizable up to 3 meters (typically)
Thread 5/8-18 UNS-2A
Frequency Range Typically up to 10 kHz
Operating temperature -40°F to 248°F
3300 XL 8 mm Proximity Transducer
Sensing Range ± 8 mm (0.315 inches)
Sensing Technology Eddy current technology
Customizable up to 3 meters (typically)
Thread 5/8-18 UNS-2A
Frequency Range Typically up to 10 kHz
Operating temperature -40°C to +120°C
3300 XL 8 mm Proximity Transducer
Probe Tip Diameter 8 mm
Probe Length 10 inches (254 mm)
Thread Size 5/8-18 UNF-2A
0 to 4.0 mm (160 mils) linear displacement range
3.94 mV/μm (100 mV/mil) nominal
Less than 0.5 μm (20 μin) under stable conditions
-51°C to +100°C (-60°F to +212°F)
Up to 90%, non-condensing
3300 XL 8 mm Proximity Transducer
Probe Tip Diameter 8 mm
Probe Length 12 inches (354 mm)
Thread Size 5/8-18 UNF-2A
0 to 4.0 mm (160 mils) linear displacement range
3.94 mV/μm (100 mV/mil) nominal
0 to 10 kHz (±3 dB)
Less than 0.5 μm (20 μin) under stable conditions
-51°C to +100°C (-60°F to +212°F)
Up to 90%, non-condensing
3300 XL 8 mm Proximity Probes
Probe Tip Diameter 8 mm
Probe Length 10 inches (254 mm)
Thread Size 5/8-18 UNF-2A
0 to 4.0 mm (160 mils) linear displacement range
3.94 mV/μm (100 mV/mil) nominal
0 to 10 kHz (±3 dB)
Less than 0.5 μm (20 μin) under stable conditions
-34°C to +177°C (-30°F to +350°F)
Up to 90%, non-condensing
3300 XL 8 mm Proximity Probes
Probe Tip Diameter 8 mm
Probe Length 10 inches (254 mm)
Thread Size 5/8-18 UNF-2A
0 to 4.0 mm (160 mils) linear displacement range
3.94 mV/μm (100 mV/mil) nominal
0 to 10 kHz (±3 dB)
Less than 0.5 μm (20 μin) under stable conditions
-34°C to +177°C (-30°F to +350°F)
Up to 90%, non-condensing
3300 XL 8 mm Proximity Probes
Probe Tip Diameter 8 mm
Probe Length 5 inches (127 mm)
Thread Size 5/8-18 UNF-2A
0 to 4.0 mm (160 mils) linear range
4.0 mV/μm (100 mV/mil) nominal
<0.5 μm (20 μin) under stable conditions
-34°C to +177°C (-30°F to +350°F)
Up to 90%, non-condensing
3300 XL 11 mm Proximity Transducer System
Probe Tip Diameter 11 mm
System Length 60 inches (5 ft)
Thread Size 5/8-18 UNF-2A
0.5 to 4.5 mm (20 to 180 mils) linear range
3.94 V/mm (100 mV/mil)
-34°C to +177°C (-30°F to +350°F) for the probe
3300 XL 11 mm Proximity Transducer
Probe Tip Diameter 11 mm
System Length 19 ft system length
Thread Size M14 x 1.5
0 to 4.0 mm (160 mils) linear range
<0.5 μm (20 μin) under stable conditions
-51°C to +100°C (-60°F to +212°F)
7.87 mV/μm (200 mV/mil) nominal
Up to 90%, non-condensing
3300 XL 11 mm Proximity Transducer
Probe Tip Diameter 11 mm
System Length 22 ft
Thread Size 3/8-24 UNF-2A
-51°C to +100°C (-60°F to +212°F)
0 to 4.0 mm (160 mils) linear range
7.87 mV/μm (200 mV/mil) nominal
Up to 90%, non-condensing
3300 XL 8 mm proximity probe
Probe Tip Diameter 8 mm
System Length 36 ft
Thread Size 3/8-24 UNF-2A
AISI 304 Stainless Steel
Miniature coaxial connector, click-on style
0 to 2.0 mm (80 mils) linear range
-34°C to +177°C (-30°F to +350°F)
-51°C to +177°C (-60°F to +350°F)
Up to 90%, non-condensing
3300 XL 8 mm Proximity Transducer
Probe Tip Diameter 8 mm
System Length 5 ft
Thread Size M10 x 1
AISI 304 Stainless Steel
Miniature coaxial connector, click-on style
0 to 2.0 mm (80 mils) linear range
7.87 mV/μm (200 mV/mil) nominal
-34°C to +177°C (-30°F to +350°F)
Up to 90%, non-condensing
3300 XL 8 mm Proximity Transducer
Probe Tip Diameter 8 mm
System Length 50 ft
Thread Size 5/8-18 UNF-2A
AISI 304 Stainless Steel
0 to 2.0 mm (80 mils) linear range
-34°C to +177°C (-30°F to +350°F)
Up to 90%, non-condensing
3300 XL NSv Proximity Transducer
3300 XL NSv (Narrow Side View)
Probe Tip Diameter 5 mm
System Length 20 ft
AISI 304 Stainless Steel
0 to 1.0 mm (40 mils) linear range
<0.2 μm (8 μin) under stable conditions
-34°C to +177°C (-30°F to +350°F)
3300 XL REVERSE MOUNT PROBE
Reverse Mount
8 mm tip diameter
System Length 12 ft
3/8-24 UNF-2A
AISI 304 Stainless Steel
0 to 2 mm (80 mils) linear measurement range
7.87 mV/μm (200 mV/mil) nominal
0 to 10 kHz (±3 dB)
Extension Cable
Armored and Unarmored Options
Multiple Connector Options
Complete Interchangeability of Units and Cabling
-51 degrees Celsius to +177 degrees Celsius